Skip to main content
ARS Home » Northeast Area » Boston, Massachusetts » Jean Mayer Human Nutrition Research Center On Aging » Research » Publications at this Location » Publication #161686

Title: USE OF D-T PRODUCED FAST NEUTRONS FOR IN VIVO BODY COMPOSITION ANALYSIS: A REFERENCE METHOD FOR NUTRITIONAL ASSESSMENT IN THE ELDERLY

Author
item KEHAYIAS, JOSEPH - TUFTS-HNRCA

Submitted to: Analytical and Bioanalytical Chemistry
Publication Type: Proceedings
Publication Acceptance Date: 12/15/2003
Publication Date: 1/28/2004
Citation: Kehayias, J.J. 2004. Use of D-T produced fast neutrons for in vivo body composition analysis: a reference method for nutritional assessment in the elderly. In: Proceedings of the International Conference on Isotopic and Nuclear Analytic Techniques for Health and Environment. June 10-13, 2003, Vienna, Austria. Analytical and Bioanalytical Chemistry. 379:188-191.

Interpretive Summary:

Technical Abstract: Body composition has become the main outcome of many nutritional intervention studies including osteoporosis, malnutrition, obesity, AIDS and aging. Traditional indirect body composition methods developed with healthy young adults do not apply to the elderly or diseased. Fast neutron activation (for N and P) and neutron inelastic scattering (for C and O) are used to assess in vivo elements characteristic of specific body compartments. Non-bone phosphorus for muscle is measured by the 31P(n, alpha) 28Al reaction, and nitrogen for protein via the (n, 2n) fast neutron reaction. Inelastic neutron scattering is used to measure total body carbon and oxygen. Body fat is derived from carbon after correcting for contributions from protein, bone and glycogen. Carbon-to-oxygen ratio (C/O) is used to measure distribution of fat and lean tissue in the body and to monitor small changes of lean mass. A sealed, D-T neutron generator is used for the production of fast neutrons. Carbon and oxygen mass and their ratio are measured in vivo at a radiation exposure of less than 0.06 mSv. Gamma ray spectra are collected using large BGO detectors and analysed for the 4.43 MeV state of carbon and 6.13 MeV state of oxygen, simultaneously with the irradiation. P and N analysis by delayed fast neutron activation is performed by transferring the patient to a shielded room equipped with an array of NaI (Tl) detectors. A combination of measurements makes possible the assessment of the 'quality' of fat free mass. The neutron generator system is used to evaluate the efficacy of new treatments, to study mechanisms of lean tissue depletion with aging and to investigate methods for preserving function and quality of life in the elderly. It is also used as a reference method for the validation of portable instruments of nutritional assessment.