Skip to main content
ARS Home » Plains Area » Lubbock, Texas » Cropping Systems Research Laboratory » Cotton Production and Processing Research » Research » Publications at this Location » Publication #168879

Title: CORRECTING PM10 OVER-SAMPLING PROBLEMS FOR AGRICULTURAL PARTICULATE MATTER EMISSIONS: PRELIMINARY STUDY

Author
item WANG, LINGJUAN - TEXAS A&M UNIVERSITY
item PARNELL, CALVIN - TEXAS A&M UNIVERSITY
item SHAW, BRYAN - TEXAS A&M UNIVERSITY
item LACEY, RONALD - TEXAS A&M UNIVERSITY
item Buser, Michael
item GOODRICH, LEE - TEXAS A&M UNIVERSITY
item CAPAREDA, SERGIO - TEXAS A&M UNIVERSITY

Submitted to: Transactions of the ASAE
Publication Type: Peer Reviewed Journal
Publication Acceptance Date: 6/15/2004
Publication Date: 2/5/2005
Citation: Wang, L., Parnell, C.B., Shaw, B.W., Lacey, R.E., Buser, M.D., Goodrich, L.B., Capareda, S.C. 2005. Correcting PM10 over-sampling problems for agricultural particulate matter emissions: preliminary study. Transactions of the ASAE. 48(2):749-755.

Interpretive Summary: Interpretive Summary Particulate matter (PM) pollutant has been regulated based on the National Ambient Air Quality Standards (NAAQS). The NAAQS set the limit for ambient PM concentration to protect the public health. Currently, the regulation of PM is based upon the emission concentration of PM10 measured by Federal Reference Method (FRM) PM10 samplers. By definition, PM10 are particles with diameter less than or equal to a nominal 10 micrometers. The EPA approved PM10 samplers are not 100% efficient. As might be expected, there are errors in the measurement of PM10. The accuracy of the concentration measurements of PM10 has been challenged. In fact, it has been reported that there are inherent sampling errors associated with the PM10 samplers due to the interaction of particle size distribution and sampler performance characteristics. A theoretical method is proposed to correct the sampling error problems for EPA approved PM10 samplers. The finding in this report provides a way to obtain more accurate measurements of PM10 concentrations for different particle size distribution of PM

Technical Abstract: The FRM ambient PM10 sampler does not always measure the true PM10 concentration. There are inherent sampling errors associated with the PM10 samplers due to the interaction of particle size distribution and sampler performance characteristics. These sampling errors, which are the relative differences between theoretical estimation of the sampler concentration and the true concentration, should be corrected for equal regulation between industries. An alterative method of determining true PM10 concentration is to use the TSP concentration and PM10 fraction of PSD in question. This paper reports a new, theoretical method to correct PM10 sampling errors for a true PM10/TSP ratio. The new method uses co-located PM10/TSP samplers' measurements to derive the MMD of PSD and true PM10/TSP ratio. Correction equations and charts have been developed for the PM's with GSD's of 1.2, 1.3, ... 2.1, respectively, and the PM10 sampler with a cut-point of 10 um and slope of 1.5. These equations and charts can be used to obtain a corrected PM10/TSP ratio for the given GSD and sampler characteristics. The corrected PM10/TSP ratio will be treated as true PM10/TSP ratio for PM10 concentration calculations. This theoretical process to obtain a corrected PM10/TSP ratio will minimize the inherent PM10 sampler errors and will provide more accurate PM10 measurement for the given condition.